| Specification | Value |
|---|---|
| Discrete Input Logic | positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V |
| Analogue Output Type | software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits |
| Discrete Output Type | logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA |
| Maximum Switching Current | relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC || relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
| 4 Quadrant Operation Possible | true |
| Exchange Mode | half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
| Local Signalling | local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red) |
| Data Format | 8 bits, configurable odd, even or no parity Modbus serial |
| Relative Symmetric Network Frequency Tolerance | 5 % |
| Net Weight | 10.5 kg |
| With Safety Function Safe Direction (Sdi) | false |
| Type Of Polarization | no impedance |
| Relay Output Type | configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles |
| Analogue Input Number | 3 |
| Motor Slip Compensation | automatic whatever the load || not available in permanent magnet motor law || can be suppressed || adjustable |
| Discrete Output Number | 2 |
| With Safety Function Safe Position (Sp) | false |
| Transmission Rate | 10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial |
| Method Of Access | slave Modbus TCP |
| With Safety Function Safely Limited Position (Slp) | false |
| With Safety Function Safe Operating Stop (Sos) | false |
| Number Of Addresses | 1-247 |
| Discrete Input Number | 10 |
| Linearity Error | AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output |
| Number Of Addresses | 1-247 Modbus serial |
| With Sft Fct Safe Stop 2 (Ss2) | false |
| With Safety Function Safe Stop 1 (Ss1) | true |
| Width | 264 mm |
| Transmission Rate | 10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s |
| Depth | 300 mm |
| Analogue Input Type | AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits |
| Sampling Duration | 2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output |
| Electrical Connection | control screw terminal 0.5...1.5 mm² || line side screw terminal 4...6 mm² || motor screw terminal 4...6 mm² || DC bus screw terminal 2.5...6 mm² |
| With Safety Function Safe Brake Management (Sbc/Sbt) | true |
| Height | 678 mm |
| Acceleration And Deceleration Ramps | linear adjustable separately from 0.01...9999 s |
| Maximum Output Voltage | 480.0 V |
| Base Load Current At High Overload | 4.0 A |
| Transmission Frame | RTU |
| With Safety Function Safe Speed Monitor (Ssm) | false |
| Relay Output Number | 3 |
| With Safety Function Safe Torque Off (Sto) | true |
| Data Format | 8 bits, configurable odd, even or no parity |
| Base Load Current At Low Overload | 5.6 A |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Input Compatibility | DI1...DI8 discrete input level 1 PLC EN/IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2 |
| Connector Type | 2 RJ45 || 1 RJ45 |
| Analogue Output Number | 2 |
| Physical Interface | Ethernet || 2-wire RS 485 |
| Minimum Switching Current | relay output R1, R2, R3 5 mA 24 V DC |
| Refresh Time | relay output R1, R2, R3)5 ms +/- 0.5 ms) |
| Isolation | between power and control terminals |
| With Safety Function Safe Programmable Logic | false |
| Brake Chopper Integrated | true |
| Quantity Per Set | 1 |
| Type Of Polarization | no impedance Modbus serial |
| Braking To Standstill | by DC injection |
| Discrete Input Type | DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm |
| Protection Type | thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive |
| Supply | external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection |
| With Safety Function Safely Limited Speed (Sls) | true |
| Prospective Line Isc | 50 kA |
| Network Frequency | 50-60 Hz |
| Product Destination | synchronous motors || asynchronous motors |
| Line Current | 4.3 A 380 V normal duty) || 3.1 A 380 V heavy duty) || 3.8 A 480 V normal duty) || 2.9 A 480 V heavy duty) |
| Phase | 3 phase |
| Asynchronous Motor Control Profile | variable torque standard || constant torque standard || optimized torque mode |
| Variant | with load break switch || with braking chopper |
| Product Or Component Type | variable speed drive |
| Apparent Power | 3.2 kVA 480 V normal duty) || 2.4 kVA 480 V heavy duty) |
| Ip Degree Of Protection | IP55 |
| Switching Frequency | 2...16 kHz adjustable || 4...16 kHz with derating factor |
| Maximum Transient Current | 6.7 A 60 s normal duty) || 6 A 60 s heavy duty) |
| Communication Port Protocol | Modbus serial || Modbus TCP || EtherNet/IP |
| Product Specific Application | process for industrial |
| Option Card | slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module CANopen SUB-D 9 || slot A communication module CANopen screw terminals || slot A/slot B/slot C digital and analog I/O extension module || slot A/slot B/slot C output relay extension module || slot B 5/12 V digital encoder interface module || slot B analog encoder interface module || slot B resolver encoder interface module || communication module Ethernet Powerlink |
| Degree Of Protection | UL type 12 |
| Maximum Output Frequency | 599 Hz |
| Range Of Product | Altivar Process ATV900 |
| Motor Power Kw | 2.2 kW normal duty || 1.5 kW heavy duty |
| [Us] Rated Supply Voltage | 380...480 V - 15...10 % |
| Mounting Mode | wall mount |
| Discrete Input Logic | 16 preset speeds |
| Continuous Output Current | 5.6 A 4 kHz normal duty || 4 A 4 kHz heavy duty |
| Nominal Switching Frequency | 4 kHz |
| Emc Filter | integrated || with EMC plate option |
| Device Application | Industrial Application |
| Synchronous Motor Control Profile | permanent magnet motor || synchronous reluctance motor |
Nos articles d'occasion et nos options de réparation sont assortis d'une garantie Obso de 12 mois.
"Super service ! Tout a été traité très rapidement et avec compétence et l'assistance personnelle était excellente. Je choisirai toujours Obso Automation ! Merci beaucoup pour votre soutien." - MJ
Des options de livraison standard sont également disponibles si nécessaire.
"Professionnel, courtois et précis. La pièce obsolète a fait l'objet d'un devis le jour même et a été livrée le lendemain" - PT
1
Step 1
Partie ajoutée pour enquête
2
Étape 2
Votre gestionnaire de compte personnel est déjà sur le coup et vous fournit des réponses rapides avec un service imbattable.
3
Étape 3
Nous ne nous contentons pas de traiter les commandes, nous garantissons une livraison sans heurts, une transparence totale et une absence totale de maux de tête.
4
Étape 4
Plus de 10 000 clients nous font confiance pour une bonne raison. Obtenez votre devis dès maintenant et découvrez l’automatisation sans risque, ni délai, ni incertitude.
Google Reviews