EX225T3HNLP
Schneider Electric
Transformer, dry type, DOE 2016, 225kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 25J, 150C rise, K13
Disponible
Obtenga una cotización ahora
- "EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 225kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise, K-13 rated. This transformer\u2019s DOE 2016 and NRCan efficiency is a minimum of 98.94% at 35% loading and 75\u00b0C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of 1/2 inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values."
| Specification | Value |
|---|---|
| Tap Loss | 479 no load (core loss) || 2474 load loss (coil loss) |
| Network Frequency | 60 Hz |
| Primary Voltage | 480 V delta |
| Percentage Impedance Voltage | 3.3 % |
| Height | 1461 mm |
| [Uimp] Rated Impulse Withstand Voltage | 10 kV |
| Temperature Rise | 150 °C || 220 °C insulated |
| Degree Of Protection | UL type 1 || UL type 2, with 7400DS25J || UL type 3R, with 7400WS25J |
| Number Of Tap-Offs | 2 2.5 % FCAN || 4 2.5 % FCBN |
| X/R Ratio | 2.82 |
| Rated Operational Power In Va | 225 kVA |
| Electrical Connection | 4 Hole Nema Pad primary 11.1 mm || 6 Hole Nema Pad secondary 11.1 mm || 8 Hole Nema Pad sec - XO 11.1 mm |
| Phase | 3 phase |
| Material | aluminium |
| Net Weight | 895.84 kg |
| Secondary Voltage | 208Y/120 V |
| Percentage Reactance | 0.031 % |
| Noise Level | 6 dB NEMA ST-20 || 49 dB |
| Type Of Cooling | natural convection |
| Efficiency | 99.09 % at 35 % load factor , 75.0 °C |
| Mounting Support | floor || floor, with 7400FMB |
| Continuous Thermal Current Rating Factor | 1869 16.6 % || 2162 25 % || 3745 50 % || 6383 75 % || 10076 100 % |
| Width | 1018 mm |
| Depth | 832 mm |
| Box Number | 25J |
| [Ipk] Rated Peak Withstand Current | 18.9 kA |
| Range Of Product | Square D |
| Product Or Component Type | transformer |
| Transformer Type | energy efficient |
| Device Application | low voltage electrical distribution |
| Device Short Name | DOE 2016 |
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.
«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
Si lo desea, también disponemos de opciones de entrega estándar.
«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
1
Step 1
Parte agregado para la investigación
2
Paso 2
Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.
3
Paso 3
No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.
4
Paso 4
Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.
Google Reviews