ATV650D11N4EU
Schneider Electric
variable speed drive, Altivar Process ATV600, ATV650, 11kW, 400...480V, IP55
Disponible
Obtenga una cotización ahora
- "This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 50m and 150m cable conforming to categories C2 and C3. It works at a rated supply voltage from 380V to 480VAC and it is an IP55 UL type 12 rated product. This drive provides up to 30% energy saving when on standby due to the innovative \u2018\u2018Stop and Go\u2019\u2019operation without additional costs. It is suitable for motors with power rating up to 11kW/15HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 7.5kW/10HP for applications requiring significant overload (up to 150%). Its dimensions are 264mm (width) x 330mm (depth) x 678mm (height). It weighs 19.6kg. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. This product is certified by ATEX INERIS, ATEX zone 2/22, CE, UL, CSA, BV and TUV. It meets EN/IEC 61800, IEC 61000-3-12, IEC 60721-3, IEC 61508 and IEC 13849-1 standards. It is designed to be mounted in vertical position (+/- 10 \u00b0) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process."
| Specification | Value |
|---|---|
| Discrete Input Logic | positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V |
| Analogue Output Type | software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA |
| Discrete Output Type | relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V DC 5000 mA |
| Maximum Switching Current | relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC |
| Exchange Mode | half duplex, full duplex, autonegotiation Ethernet/Modbus TCP |
| Phase | 3 phase |
| Net Weight | 19.6 kg |
| Type Of Polarization | no impedance |
| Relay Output Type | configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles || configurable relay logic R1 fault relay NO/NC 100000 cycles |
| Frequency Resolution | analog input 0.012/50 Hz || display unit 0.1 Hz |
| Maximum Transient Current | 24.8 A 60 s heavy duty) || 25.9 A 60 s normal duty) |
| Analogue Input Number | 3 |
| Motor Slip Compensation | automatic whatever the load || not available in permanent magnet motor law || can be suppressed || adjustable |
| Discrete Output Number | 0 |
| Method Of Access | slave Modbus TCP |
| Discrete Input Number | 8 |
| Local Signalling | for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red) || for local diagnostic 3 LEDs |
| Linearity Error | AO1, AO2 +/- 0.2 % analog output || AI1, AI2, AI3 +/- 0.15 % of maximum value analog input |
| Number Of Addresses | 1-247 Modbus serial |
| Width | 264 mm |
| Transmission Rate | 10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps |
| Depth | 330 mm |
| Analogue Input Type | AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits |
| Sampling Duration | 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output || 2 ms +/- 0.5 ms DI1...DI4) - discrete input |
| Electrical Connection | line side screw terminal 6 mm² || motor screw terminal 6...10 mm² || control removable screw terminals 0.5...1.5 mm² |
| Maximum Output Frequency | 500 kHz |
| Height | 678 mm |
| Acceleration And Deceleration Ramps | linear adjustable separately from 0.01...9999 s |
| Transmission Frame | RTU |
| Relay Output Number | 3 |
| Data Format | 8 bits, configurable odd, even or no parity |
| Accuracy | +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input |
| Connector Type | RJ45 on the remote graphic terminal)Modbus serial || RJ45 on the remote graphic terminal)Ethernet/Modbus TCP |
| Input Compatibility | DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2 || DI1...DI6 discrete input level 1 PLC IEC 61131-2 |
| Permissible Temporary Current Boost | 1.5 x In 60 s heavy duty) || 1.1 x In 60 s normal duty) |
| Mounting Mode | wall mount |
| Analogue Output Number | 2 |
| Physical Interface | Ethernet || 2-wire RS 485 |
| Minimum Switching Current | relay output R1, R2, R3 5 mA 24 V DC |
| Refresh Time | relay output R1, R2, R3)5 ms +/- 0.5 ms) |
| Enclosure Mounting | wall mounted |
| Isolation | between power and control terminals |
| Output Voltage | <= power supply voltage |
| Quantity Per Set | 1 |
| Braking To Standstill | by DC injection |
| Discrete Input Type | DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) |
| Protection Type | safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive || thermal protection motor |
| Supply | internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection || external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection |
| Prospective Line Isc | 50 kA |
| Product Destination | asynchronous motors || synchronous motors |
| Line Current | 17 A 480 V normal duty) || 14.1 A 380 V heavy duty) || 12.5 A 480 V heavy duty) || 19.8 A 380 V normal duty) |
| Emc Filter | integrated 50 m IEC 61800-3 category C2 || integrated 150 m IEC 61800-3 category C3 |
| Asynchronous Motor Control Profile | variable torque standard || optimized torque mode || constant torque standard |
| Variant | with disconnect switch |
| Product Or Component Type | variable speed drive |
| Apparent Power | 10.4 kVA 480 V heavy duty) || 14.1 kVA 480 V normal duty) |
| Switching Frequency | 4...12 kHz with derating factor || 2...12 kHz adjustable |
| Communication Port Protocol | Ethernet || Modbus serial |
| Product Specific Application | process and utilities |
| Safety Function | STO (safe torque off) SIL 3 |
| Maximum Horse Power Rating | 10 hp heavy duty || 15 hp normal duty |
| Supply Frequency | 50...60 Hz - 5...5 % |
| Option Card | slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A communication module, CANopen screw terminals || slot A/slot B digital and analog I/O extension module || slot A/slot B output relay extension module || slot A communication module, Ethernet IP/Modbus TCP/MD-Link || communication module, BACnet MS/TP || communication module, Ethernet Powerlink || slot A communication module, Profibus DP V1 |
| Degree Of Protection | UL type 12 UL 508C |
| Range Of Product | Altivar Process ATV600 |
| Speed Drive Output Frequency | 0.1-500 Hz |
| Ip Degree Of Protection | IP55IEC 60529 || IP55IEC 61800-5-1 |
| Motor Power Kw | 7.5 kW heavy duty) || 11 kW normal duty) |
| [Us] Rated Supply Voltage | 380...480 V |
| [Us] Rated Supply Voltage | 380...480 V - 15...10 % |
| Discrete Input Logic | 16 preset speeds |
| Type Of Cooling | forced convection |
| Continuous Output Current | 16.5 A 4 kHz heavy duty || 23.5 A 4 kHz normal duty |
| Nominal Switching Frequency | 4 kHz |
| Device Short Name | ATV650 |
| Synchronous Motor Control Profile | synchronous reluctance motor || permanent magnet motor |
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.
«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
Si lo desea, también disponemos de opciones de entrega estándar.
«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
1
Step 1
Parte agregado para la investigación
2
Paso 2
Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.
3
Paso 3
No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.
4
Paso 4
Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.
Google Reviews