METSEION92130
Schneider Electric
PowerLogic™ ION9000 meter, LVDC, DIN mount, no display, HW kit
Verfügbar
Jetzt Angebot einholen
- "The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 \u00b5s and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs of 1 A, 5 A; current class 2, 10, 20 A; Frequency of 20-450 Hz. Low voltage control power range of 20 to 60 VDC. DIN rail mounting or panel mounting (with back to back adapter) transducer, plus 2 display options, further enhance the flexibility and adaptability of the ION9000."
| Specification | Value |
|---|---|
| Product Or Component Type | energy and power quality meter |
| Range | PowerLogic |
| Device Application | power monitoring || WAGES metering || Net metering || medium voltage || high voltage |
| Device Short Name | ION92030 |
| Metering Type | demand current I1, I2, I3, I4, I5 || peak demand currents || demand power P, Q, S || peak demand power PM, QM, SM || calculated active and reactive energy (+/- W.h, +/- VAR.h) |
| [Us] Rated Supply Voltage | 20...60 V DC +/- 10 % |
| Communication Port Support | 2 RS485 removable screw terminal block |
| Power Quality Analysis | EN 50160 compliance checking || IEEE 519 harmonic limit || IEC 61000-4-30 class A compliance reporting || IEEE 519 compliance reporting || waveform capture || total demand distortion || total harmonic distortion || up to the 63rd harmonic || up to the 127th harmonic with software || disturbance direction detection || dip, swell and transient || half cycle data acquisition || transient detection (20 µs) |
| Height | 160 mm |
| Measurement Voltage | 57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases |
| Sampling Rate | 1024 samples/cycle |
| Memory Capacity | 2 GB |
| Number Of Outputs | 4 digital || 2 form C relay |
| Type Of Measurement | voltage sags and swells || current sags and swells || voltage || current || frequency || active and reactive power total || apparent power total || active and reactive power per phase || apparent power per phase || power factor total || power factor per phase || active and reactive energy || apparent energy || harmonic distorsion (I THD & U THD) |
| Communication Port Protocol | Modbus RTU 2400...115200 bps - 2-wire || ION 2400...115200 bps - 2-wire || DNP3 2400...115200 bps - 2-wire || Modbus TCP 10/100 Mbit/s || ION TCP 10/100 Mbit/s || DNP3 TCP 10/100 Mbit/s || IEC 61850 || Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s || DHCP || DNS || DLMS |
| Frequency Measurement Range | 20-450 Hz |
| Communication Service | compliant reports || power quality summary || energy report || EcoStruxure Power Events Analysis || SMTP e-mail notification || SNMP |
| Ride-Through Time | 500 ms 60 V DC typical |
| Port Ethernet | 10/100BASE-TX 2 RJ45 |
| Power Consumption In Va | 15 W 20...60 V DC |
| Net Weight | 1.5 kg |
| Tamperproof Of Settings | protected by sealable cover |
| Measurement Current | 0.01-20 A |
| Electrical Insulation Class | class III EN/IEC 62052-11 |
| Number Of Inputs | 8 digital 30 V AC/60 V DC |
| Time Synchronisation Protocol | GPS || IRIG-B || NTP || SNTP || PTP |
| Measurement Accuracy | voltage +/- 0.1 % || current +/- 0.1 % |
| Ethernet Service | DHCP client || Device Profile Web Services (DPWS) || Rapid Scanning Tree Protocol (RSTP) || FTP/HTTP/HTTPS |
| Mounting Support | DIN rail |
| Communication Gateway | Ethernet/serial |
| Poles Description | 3P + N + E |
| Data Recording | time stamping || min/max of instantaneous values || user-definable data logs || continuous logging or snapshot || trending/forecasting || event logs || alarm logs || configuration change || power outage || user login/logout || data logs || GPS synchronisation || sequence of event recording |
| Line Rated Current | 1 A || 5 A |
| Cybersecurity | Syslog protocol support || robust security logs || port hardening || enable/disable communication ports || hardware metrology lock |
| Isolation Voltage | III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3 |
| Analogue Input Type | voltage (impedance 5 MOhm) || external CT (impedance 0.3 mOhm)5 x |
| Web Services | viewing of captured waveform || web page || pass/fail report for IEEE 519 || pass/fail report for EN 50160 || ITIC (CBEMA) curve || SEMI curve || NEMA motor derating curve || alarm notification by e-mail || TLS 1.2 || push historical data via mail |
| Width | 160 mm |
| Display Type | Without Display |
| Depth | 135.3 mm |
| Accuracy Class | class 0.1S active energy IEC 62053-22 || class 0.1 active energy IEC 61557-12 || class 0.1 active energy ANSI C12.20 || class 0.5S reactive energy IEC 62053-24 || class 0.1 current IEC 61557-12 || class 0.1 voltage IEC 61557-12 || class 0.1 active power IEC 61557-12 || class 0.5 power factor IEC 61557-12 |
| Maximum Power Consumption In Va | 38 W 20...60 V DC |
Auf unsere gebrauchten Artikel und Reparaturoptionen gewähren wir 12 Monate Obso-Garantie.
„Super Service! Alles wurde sehr schnell und kompetent abgewickelt und die persönliche Betreuung war hervorragend. Ich würde mich jederzeit wieder für Obso Automation entscheiden! Vielen Dank für die tolle Unterstützung.“ - MJ
Bei Bedarf sind auch Standardoptionen für die Lieferung verfügbar.
„Professionell, zuvorkommend und genau. Veraltetes Teil am selben Tag angeboten und am nächsten Tag geliefert“ - PT
1
Step 1
Bauteil zur Anfrage hinzugefügt
2
Seite 2
Ihr persönlicher Kundenbetreuer ist bereits dabei und sorgt für schnelle Antworten und einen unschlagbaren Service.
3
Seite 3
Wir wickeln nicht nur Aufträge ab – wir garantieren eine reibungslose Lieferung, volle Transparenz und keine Kopfschmerzen.
4
Seite 4
Mehr als 10.000 Kunden vertrauen uns aus gutem Grund. Fordern Sie jetzt Ihr Angebot an und erleben Sie Automatisierung ohne Risiko, Verzögerungen oder Unsicherheit.
Google Reviews